MOD CUBE

Automatic analysis of the control of the global performances of the automatic patient repositioning system in IGRT or SGRT using the treatment table

Quote

Connected to the QUALIMAGIQ platform, it takes the MOD-CUBE module only 2 mouse clicks to analyse the many DICOM images (high and low energy portal images and tomographic slices) acquired during control of the global performances of the automatic patient repositioning system by IGRT or sgrt.

 

This test is decisive for the precision of patient repositioning based on this automatic system. It is a global test as it tests the whole repositioning sequence: acquisition of images beneath the treatment machine, resetting of these images on the reference images, automatic​ shifting of the treatment couch based on this resetting.

 

The QUALIMAGIQ software performs the following automatic analysis operations:

 

  •  Test N°1 – Cube or sphere (QUALIFORMED OTP-ISO+ test object) aligned on the isocentre positioning lasers: analysis of the 2D-MV and 2D-kV images (one image in lateral incidence and another in anterior incidence) of the cube or sphere aligned on the isocentre positioning lasers to control the gantry angles (MV images) and the alignment of the the MV and kV imagers used in  planar (2D) mode on the isocentre positioning lasers.
  •  Test N°2 – Cube or OTP-ISO+ sphere aligned on the isocentre positioning lasers: analysis of the CBCT (3D-kV) images of the cube or sphere aligned on the isocentre positioning lasers to control the alignment of the marker of the kV imager used in CBCT mode on the isocentre positioning lasers.
  •  Test N°3 – Cube or OTP-ISO+ sphere voluntarily moved by 3 known translations in the 3 directions in space by means of movements of the patient support: analysis of the CBCT images of the cube voluntarily misaligned to control the reality of the 3 voluntary shifts of the patient support. 
  •  Test N°4 – Cube or OTP-ISO+ sphere automatically reset with the patient repositioning software: analysis of the CBCT images of the cube realigned to control the quality of the resetting proposed by the automatic patient repositioning software.

Specifications

 

Less than 15 minutes is all the time you need to perform the entire control: installation of the test object, image acquisition and analysis, editing of 6 different PDF analysis reports and a trend curve for each tested parameter.

 

Associated test objects:

Any one of QUASAR Penta-Guide cube from MODUS Medical, CIRS 023 ISO CUBE from CIRS, VARIAN cube or the OTP-ISO+ sphere from QUALIFORMED.

Resources

You need a user manual? please contact us.

Your brochure request has been added to your Download Cart.

 

At the end of your visit:

 

  • Please click the "YOUR DOWNLOADS" button at the top right,
  • Complete the form and SEND it.

 

You will get the documents shortly by email.